Temperature Monitoring in SimpleTMS: Sensors and Deviations During a Trip
18 November 2026
updated at: 10 November 2026
3 min
The temperature control has been compromised, and you only find out about it when you receive the shipment
Temperature Monitoring in the SimpleTMS Dispatch Center for Temperature-Sensitive Cargo
Due to an error in the refrigeration unit’s settings, the temperature inside the refrigerated truck exceeded the permissible limits, and the distribution network refused to accept the shipment. This could have been corrected en route, but the order and trip are stored in the TMS, while the sensor readings are in the monitoring system, so the logistics specialist has to reconcile them manually. The SimpleTMS dispatch center aggregates this data into a single shipment record and displays the deviation while the cargo is still in transit.
Where the shipment Gets Lost
Food manufacturers, retailers, or logistics operators usually notice the problem too late. By the time the shipment is received, it’s already too late to replace the truck or reschedule the delivery window. Meanwhile, temperature data is available but isn’t visible next to the order.
How the dispatch center monitors temperature
The logistics specialist sets the acceptable temperature range for the entire order or for a specific shipment, whether it’s a full truckload (FTL) or less-than-truckload (LTL) shipment. During planning, the system compares the range with the temperature conditions of the vehicle and its compartments, checks the compatibility of cargo within a single compartment, and verifies the presence of monitoring equipment if required by the cargo.
During the trip, readings from connected sensors are recorded in the shipment record and linked to the vehicle or compartment. Temperature monitoring takes cargo handling operations into account, thereby eliminating false alarms in complex shipments where multiple cargoes are distributed across different points along the route. The dispatcher sees the current temperature on the map next to the permissible range.
The system distinguishes between three types of deviations: “Above Range,” “Below Range,” and “No Data.” For each deviation, the system records the start time, duration, extreme temperature (the greatest deviation from the range), and the time when the temperature returned to normal. The incident is linked to a specific point on the route.
The logistics manager selects the level of monitoring based on the cargo’s requirements.
Mode | Sensor Readings | Deviations | Automatic incident |
No monitoring | Not recorded | Not recorded; the mode is considered a transportation requirement | None |
Data recording | is saved | Recorded in the flight history | No |
Monitoring with alerts | Stored | Recorded in the flight history | Yes, when the deviation lasts longer than the allowed time |
What Temperature Monitoring Does Not Do
SimpleTMS does not control the refrigeration unit or change sensor settings. It receives data, analyzes it, and logs incidents. The system supports both standard and standalone sensors, allowing us to accommodate customer preferences.
What changes for the logistics manager
Deviations become visible while the cargo is still in transit. The responsible employee has time to replace the vehicle or reschedule the delivery window. After the trip, the deviation history remains in the shipment record for further analysis.
Temperature monitoring works in conjunction with shipment execution monitoring and route planning.
For more details, see the temperature control for shipments page.

